Products
- Filter acts as a barrier to protect the nose cone of pipettor and sample from contamination but does not impede airflow.
- Filter material is hydrophobic and does not contain additives that can contaminate; nor will it absorb samples.
- DNase, RNase, DNA, PCR inhibitors, and endotoxin-free Autoclavable.
- Less Fluid Retention Less Sample Loss Less Time Spent Less Plastic Wasted
Specification:
Volume: 5 ml
Description: Racked, sterile, filtered
Color: Natural
Packing: 1 Rack with 50 tips
- Manufactured from High-Density Polyethylene.
- More accurate than serological pipettes when measuring large volumes of solution.
- DNase, RNase, DNA, PCR inhibitors, and endotoxin free Autoclavable.
- Less Fluid Retention Less Sample Loss Less Time Spent Less Plastic Wasted
Specification:
Volume: 5 ml
Description: Racked, sterile, Un-filtered
Color: Natural
Packing: 1 Rack with 50 tips
- 0.1 and 0.2ml 8-Strip with separate cap-strip capping
- 0.1 and 0.2ml 8-Strip with separate cap-strip decapping
- 0.2ml 8-Strip with attached cap decapping
- 0.2ml PCR single tube decapping
- 1.5/1.7ml microcentrifuge tube decapping
- Adhesive film Scrapping to ensure tight adhesion between film and PCR plate
Packaging: 1 Unit/pack
- Loose 8 Cap Strips Polypropylene SBS dimensions.
- Ideal for automation / HTS. 8 × 12 format.
- Individual tubes, strips of 8 tubes, and strips of 12 tubes.
- Polypropylene is used for tubes and racks. Strip Caps are polyethylene.
Ideal for:
Storage, dilution, mixing, harvesting, culture assays, screening.
This rack and tube system is equally suitable as a reaction vessel in your robotic workstation or as a long-term storage vessel in your sample library.
A clear rack lid is a standard part of this system package. Strip caps are also available.
Packing: 1 bag with 125 Caps
- Flat Strip Caps Manufactured with virgin, medical-grade polypropylene.
- Strips of flat or dome caps.
- Optically clear for (real-time) qPCR.
- DNase, RNase, DNA, endotoxin, and PCR inhibitor-free. Flat cap, strips of 8
Packing: 1 bag with 125pcs of Caps
- 9x9 well storage (81-wells total)
- PC boxes with 4 assorted colors: red, yellow, green, and blue
- Holds 0.5ml, 1.5ml, or 2.0ml microtubes and cryogenic vials
- PC box with Removable lid includes a numbered grid for orientation
- Format: 9 rows x 9 columns
- Dimensions: 133 x 133 x 54mm
- Max Tube Dimensions: 12mm diameter, 49mm high
Packing: 1 box with 5 units
FEATURES:
- Operating Temperature -80 ~ 120℃
- PCR or Storage use
- Strongly adhesive
- Free of DNase, RNase, DNA, PCR Inhibitor, ATP, Endotoxin.
- All products are ready to use in PCR
- Evaporation rate below 5%, saving cost on reagents
- Small package can avoid contamination by different researchers
Packing: 100 Membrane/Box
- Universal fit to standard 96 well blocks; a polypropylene plate with 0.25 ml wells, black grid reference, and a cut corner at H12 Specification
Compatible with universal standard block thermal cyclers and sequencers Ultra-smooth, uniform, thin-walled polypropylene tubes for optimum PCR and real-time (RT, qPCR) results
- Maximum thermal conductivity for efficient heat transfer and precise thermal cycling
- Raised well rims prevent cross-contamination and facilitate effective sealing for reduced evaporation
- Super clear wells maximize sample visibility Compatible with standard multichannel pipettes
- Subject to a strict QC procedure which includes a visual check and leak testing of every tube Standard 0.25 ml (250 µl) working volume, with a 0.3 ml (300 µl) total volume when used with sealing option
- White plate ideal for qPCR, giving optimal signal-to-noise ratio for fluorescence-based assays
Packing: 50 Plates
- Pierceable silicon rubber sealing mat
- Suitable for heat sealing Specification:
Material: Silicone
Dimensions: Total length of 4.67” total width of 2.90”
Packing: 5pcs of silicone Cap Mat
- Plates have thin walls for excellent thermal transfer in PCR procedures
- The 96 well configuration makes them compatible with 96 well thermal cyclers.
- Can be sealed with adhesive sealing films or cap strips.
Plate Type: Chimney Top, Standard
Packing: 10 Plates
- High-contrast, black alphanumeric indexing for easy well identification.
- Crystal-clear wells to easily verify sample volume.
- Ultra-thin, uniform wells ensure optimal heat transfer for high reaction efficiency.
- Well ridges reduce sample evaporation when sealing with film, foil, or strip caps.
- Manufactured from high-clarity, ultra-pure polypropylene (meets FDA 21 CFR 177.1520 & USP Class VI).
- Non-skirted item is also available in 24 and 48 well size options. Please inquire for more details.
- Certified free of detectable DNase, RNase, DNA, PCR inhibitors, and tested pyrogen-free.
Packing: 20 Plates
This transparent polyester-based film has a medium-strength adhesive. It is designed as a low-cost sealing option and useful for temporary storage and as a cover for applications such as centrifugation. And tabs allow for easy application and removal. This seal is removable without residue on the plate. Specification
- Non-pierceable
- Peelable
- Seal integrity range: -20°C to 80°C
- Application: Sample storage (aqueous)
- Sheets: 135mm x 80mm
- Roll: 110m x 80mm
Packing: 100 Sheets
The Biocen 22 R can reach up to 30.034 xg , becoming the necessary tool for most demanding labs. Allows 24 microtubes of 2.2 ml, 32 of 0.2 ml and 8x15 ml, conical.
Usually microcentrifuges work with samples sensitive, valuables, or dangerous ( toxic, radioactive, infectious). Ortoalresa has built the Biocen 22 R with several advantages which allow a safe analysis, without interaction of centrifuge, as:
- Cooling system which maintains the sample temperature at 4°C at max speed,
regardless of the rotor. - Chamber of centrifugation in stainless steel, allowing an easy disinfection on samples
leakages, avoiding contamination form the centrifuge. - Rotors with hermetic lids.
- Accessories sterilizables.
User Friendliness
- LCD screen shown RPM/RCF (on steps 100 RPM/10xg),time, temperature (1°C steps) and braking (1 second steps).
- Intuitive handling through start, stop, short spin and lid keys.
- Rotor list on memory.
- Timer count up/down, from 0 or at “set RPM/RCF” for test reproducibility.
- Short spin key with speed adjustable.
- Automatic rotor recognition.
- Acceleration and braking selectable by operator.
- 15 memories and pre-cooling program.
- Automatic open lid.
- Lid latch lock.
- Microprocessor controlled.
- Option: free or locked adjustment of RPM/RCF along the run.
Features
- Induction motor maintenance free
- Max. capacity 8 x 15 ml.
- Speed, up to 30.034 xg/18.100 RPM.
- Quiet: noise level < 60 dB.
Safety
- Lid locking and holding.
- Imbalance switch off.
- Manual overriding.
- Chamber of centrifugation in stainless steel.
- Viewing and calibration port in the lid.
- Several messages keep the operator informed about the device situation.
- Guard ring between the chamber of centrifugation and the housing.
- Lid dropping protection.
Cooling
- Precooling program with rotor spinning and temperature selectable by operator.
- 4°C at Max speed as higher.
- Temperature range from -20°C (-4°F) to 40°C (104°F).
- Temperature sensor inside the chamber, gas R 404A HFC.
Standards and EC Directives
EU Directives: 98/79/EC, 2006/95/EC, 2004/108/EC, 2011/65/EU, 2012/19/EU.
Regulation: 1005/2009 & 842/2006.
Standards: EN 61010-1, EN 61010-2-020, EN 61326-1.
Versions
Code |
Dimensions (mm)(w x d x h) |
Net weight (Kg) |
Voltage (V) |
Frecuency (Hz) |
Consumption (W) |
||
CE 148 |
276 |
640 |
272 |
34 |
220-240 |
50-60 |
540 |
CE 149 |
276 |
640 |
272 |
34 |
110-120 |
50-60 |
540 |