SPECIAL APPLICATION CENTRIFUGES

Shop By
translation missing: en.products.product.regular_price Please request a quotation
translation missing: en.products.product.regular_price Please request a quotation

Max. Capacity: 12 butyrometers
Max. Speed: 224 xg / 1,200 RPM

Centrifuge designed for the determination of fat in dairy products (cheese, milk, yogurt ...) following the procedure of the Gerber method.

Code Dimensions (mm) (axlxh) Net weight / kg) Voltage (v) Frequency (Hz) Consumption (w) Heating
CE 158 365 300 450 2. 3 220-230 fifty 500 YES
CE 159 365 300 450 2. 3 110-120 fifty 480 YES

 

Compatible rotors:

RT 241
RT 241

Rotor: Angular 20º
Cap. Max: 12 butyrometers
RPM Max .: 12,000
Radius (mm): 139
FCR Max (xg): 224

RT 240
RT 240

Rotor: Angular 20º
Cap. Max .: 8 butyrometers
RPM Max .: 1,200
Radius (mm): 139 FCR Max (xg): 224

Download Datasheet

 

translation missing: en.products.product.regular_price Please request a quotation
translation missing: en.products.product.regular_price Please request a quotation

Max capacity: 4 x 100 ml. (8/6 ")
Max Speed: 2.425 xg / 3.000 RPM

The most affordable option within the range of centrifuges for oils for those laboratories that, by the standards that apply, do not need heating. It has the same accessories as the heated versions, all of them are specially designed to work with oily substances as well as with the reagents   used in the standards for oil applications.

Effective, fast, versatile, it allows to work both with 6 "and 8" conical   tubes, pear tubes and "finger" tubes for small volumes. It has the pre-installation for the incorporation of the gas release system at any time throughout the life of the equipment.

Designed for oils according to standards: ASTM D 91, D 893, D 2273, D 2709, D 5546, API 2542, API 2548, BS 4385, DIN 51793.

Tubes at rest positioned vertically.

Gas Release System (GRS): Sist. gas release (optional); equipment with pre-installation.

TFT color touch screen, visible to more than 3 m:

  • RPM and FCR indicator, time, acceleration / braking (PCBS) and unbalance localization system (ULS).
  • Programmable speed in steps of 10 RPM / 10 xg.
  • Real FCR values ​​on the screen depending on the adapters.
  • Countdown / rising from "0" or "set RPM / FCR" for reproducible results.
  • 1 min clock at 99 hours programmable in 1-second intervals. and indefinite time.
  • PCBS: Progressive controllable acceleration and braking system with up to 175 selectable ramps that prevent homogenization of the sample after separation.
  • ULS: Unbalance localization system, which indicates on the screen the number of the vessel that produces the unbalance stop.
  • 40 programmable memories with password protection.
  • Acoustic and visual messages on the screen showing the user the status of the equipment.

 

Compatible rotors:

RT 220
RT 220

Rotor: Oscillating
Cap. Max .: 4 x 100 ml. (8 ")
Max. RPM: 3,000
Radius (mm): 241
FCR Max. (xg): 2.425

RT 239
RT 239

Rotor: Oscillating
Cap. Max .: 4 x 100 ml. (8/6 ")
Max. RPM: 3,000
Radius (mm): 241
FCR Max. (xg): 2.425

Download Datasheet

 

translation missing: en.products.product.regular_price Please request a quotation
translation missing: en.products.product.regular_price Please request a quotation

Max capacity: 4 x 100 ml. (8/6 ")
Max Speed: 2.425 xg / 3.000 RPM

With capacity for 4 tubes of 8 ", 6", trace and   28 tubes type "finger" .Versátil and effective the best option of all centrifuges for applications in oils.

 

Designed for petroleum according to standards: ASTM D 91, D96, D 893, D 1796, D2273, D2709, D 2711, D 4007, D 5546, API 2542, API 2548, BS 4385, ISO 3734, ISO 9030, IP75, IP 359 , NF M07-020, DIN 51793.

Tubes at rest positioned vertically.

Gas Release System (GRS) : System gas release (optional); equipment with pre-installation.

TFT color touch screen, visible to more than 3 m:

  • Indicator of RPM and FCR, time, temperature, acceleration / braking (PCBS) and unbalance localization system (ULS).
  • Programmable speed in steps of 10 RPM / 10 xg.
  • Real FCR values ​​on the screen depending on the adapters.
  • Countdown / rising from "0" or "set RPM / FCR" for reproducible results.
  • 1 min clock at 99 hours programmable in 1-second intervals. and indefinite time.
  • PCBS: Progressive controllable acceleration and braking system with up to 175   selectable ramps that prevent homogenization of the sample after separation.
  • ULS: Unbalance localization system, which indicates on the screen the number of the vessel that produces the unbalance stop.
  • 40 programmable memories with password protection.
  • Acoustic and visual messages on the screen showing the user the status of the equipment.

 

Compatible rotors:

RT 220
RT 220

Rotor: Oscillating
Cap. Max .: 4 x 100 ml. (8 ")
Max. RPM: 3,000
Radius (mm): 241
FCR Max. (xg): 2.425

RT 239
RT 239

Rotor: Oscillating
Cap. Max .: 4 x 100 ml. (8/6 ")
Max. RPM: 3,000
Radius (mm): 241
FCR Max. (xg): 2.425

RT 245 (2) (3)
RT 245 (2) (3)

Rotor: Oscillating
Max. Capacity: 10/6/2/2 microplates
RPM: 4,500
Radius mm .: 166
FCR Max (xg): 3.758
* Only available for refrigerated models.

Download Datasheet

 

translation missing: en.products.product.regular_price Please request a quotation
translation missing: en.products.product.regular_price Please request a quotation

Max capacity: 8 x 9/15 ml.
Max Speed: 1,288 xg / 3,000 RPM

The plasma concentration processes for obtaining both the fibrin and platelets network by means of PRP (platelet-rich plasma), PRF (fibrin-rich plasma) and its derivatives, make the use of the Plasma 22 centrifuge indispensable. The simplicity of these processes erroneously transmits the possibility that the performance of the technique is not affected by the centrifugation process. Nothing further from reality; the maximum performance will only be obtained with those equipment that have been validated and, in which the operating parameters, beyond RPM, RCF and time, have been calculated   for these processes.  The Plasma 22 centrifuge has been developed in conjunction with references in the development of these techniques and has the approval for the development of them.

It maintains the cellular structure of the phases for the application to each of the alternatives, ensuring that its effectiveness in the target environment and avoiding interferences of particles that prevent adhesion.

LCD screen:

  • Indicator of RPM and FCR, time and acceleration / braking (PCBS).
  • Programmable speed in steps of 50 RPM / 50 xg.
  • Countdown / rising from "0" or "set RPM / FCR" for reproducible results.
  • Clock from 1 to 99 min. programmable in 5 sec intervals. and indefinite time.
  • PCBS: Progressive controllable acceleration and braking system with up to 175 selectable ramps that prevent homogenization of the sample after separation.
  • 16 programmable memories. Performance: 8 samples in 8 minutes.
  • Acoustic and visual messages on the screen showing the user the status of the equipment.

Compatible rotors:

RT 237
RT 237

Rotor: Oscillating
Cap. Max .: 8 x 9/15 ml.
Max. RPM: 3,000
Radius (mm): 128
FCR Max. (xg): 1,288

Download Datasheet

 

translation missing: en.products.product.regular_price Please request a quotation
translation missing: en.products.product.regular_price Please request a quotation

Max capacity: 4 x 2.2 ml.
Max Speed: 839 xg / 2,500 RPM

The Ortoalresa cytocentrifuge is designed for the concentration of biological samples on a visible surface under a microscope, and its subsequent identification   and characterization.

Easy handling that reduces handling time, essential features in   oncology, cytology, hematology, virology and microbiology services.

It has an oscillating rotor for 4 supports, with two positions that allows the recovery of the filtrate for a second processing. It also has the advantage of adapting rotors for tubes, microtubes or plates.

Sealed supports that prevent the exit of the sample, easy to use.

Rapid identification of microorganisms.

It allows detection of cells even in low concentrated fluids.

Processing time <15 min.

Alarm to avoid drying the samples every 20 sec.

Possibility of using rotors for tubes (see accessories Digify 21 )

LCD screen:

  • Indicator of RPM and FCR, time and acceleration / braking (PCBS).
  • Programmable speed in steps of 50 RPM / 50 xg.
  • Countdown / rising from "0" or "set RPM / FCR" for reproducible results.
  • Clock from 1 to 99 min. programmable in 5 sec intervals. and indefinite time.
  • PCBS: Progressive controllable acceleration and braking system with up to 175 selectable ramps that prevent homogenization of the sample after separation.
  • 16 programmable memories.
  • Acoustic and visual messages on the screen showing the user the status of the equipment.

Compatible rotors:

RT 207
RT 207

Rotor: Oscillating
Cap. Max .: 4 x 2.2 ml.
Max. RPM: 2,500
Radius (mm): 120
FCR Max. (xg): 839
Cytocontainers: 4

Download Datasheet

 